• Home
  • About
  • News
  • Products
    • CALPAS Products >
      • CALPAS-V
      • CALPAS-VR
      • CALPAS-R
      • CALPAS-F
      • CALPAS-W
      • CALPAS-K
      • CALPAS-T
      • Qualifications
    • Linkoptik Products >
      • LT2200
      • LT2200E
      • LT3600
      • LT3600 Plus
      • Hydrolink
      • Hydrolink SE
      • Hydrolink SV
      • Aerolink
      • Spraylink
      • Qualifications
    • DSV Products >
      • Y501 Viscometer
      • DSV Packages >
        • Manual Package
        • Autosampler Package
        • Semi-Automation Package
        • Full Automation Package
      • Backflush Kit
    • GPC/SEC Products >
      • Aqueous Columns
      • Organic Columns
      • Specialty Columns
      • Standards
  • Services
  • Learning
    • Linkoptik Learning >
      • Linkoptik Application Notes
    • DSV Learning >
      • Principles of Dilute Solution Viscosity
      • DSV Application Notes
      • Troubleshooting FAQ
      • DSV Demo Videos
      • QuickStart Guide
      • Reboot Protocol
      • DSV School
    • GPC/SEC Learning >
      • GPC/SEC Application Notes
  • Support
    • Linkoptik Technical Support
    • DSV Technical Support
  • Contact Us
Houston MJ Associates
  • Home
  • About
  • News
  • Products
    • CALPAS Products >
      • CALPAS-V
      • CALPAS-VR
      • CALPAS-R
      • CALPAS-F
      • CALPAS-W
      • CALPAS-K
      • CALPAS-T
      • Qualifications
    • Linkoptik Products >
      • LT2200
      • LT2200E
      • LT3600
      • LT3600 Plus
      • Hydrolink
      • Hydrolink SE
      • Hydrolink SV
      • Aerolink
      • Spraylink
      • Qualifications
    • DSV Products >
      • Y501 Viscometer
      • DSV Packages >
        • Manual Package
        • Autosampler Package
        • Semi-Automation Package
        • Full Automation Package
      • Backflush Kit
    • GPC/SEC Products >
      • Aqueous Columns
      • Organic Columns
      • Specialty Columns
      • Standards
  • Services
  • Learning
    • Linkoptik Learning >
      • Linkoptik Application Notes
    • DSV Learning >
      • Principles of Dilute Solution Viscosity
      • DSV Application Notes
      • Troubleshooting FAQ
      • DSV Demo Videos
      • QuickStart Guide
      • Reboot Protocol
      • DSV School
    • GPC/SEC Learning >
      • GPC/SEC Application Notes
  • Support
    • Linkoptik Technical Support
    • DSV Technical Support
  • Contact Us
Picture

DSV Autosampler Package

Adding the autosampler to the Manual package adds automated sample introduction to the relative viscometer.  The user is responsible for weighing the sample, dispensing solvent, and dissolving the sample.  The DSV system will inject the sample, analyze the sample, and record the viscosity data.  The Autosampler Package increases sample throughput, efficiency, and productivity while improving operator safety. 
Download Brochure
Request a Quote
  • Description
  • Product Specifications
<
>
 The Autosampler Package includes the following components:
  • Relative Viscometer
  • Single syringe pump
  • Degasser
  • Data system
  • Autosampler
  • Installation and training​
Y501 relative viscometer
Specification
 
Measuring Principle
Dual capillary bridge
Measuring Ranges
0-20 cp (mPa s) or 1-10 Relative Viscosity
Sensitivity
0.0001 Specific Viscosity
Precision of RV Measurement
+/- 0.5% relative standard deviation
Typical Flowrate
1-3 ml/min
Typical Analysis Time
2-4 min
​Typical Sample Volume
30-35 ml for two injections
Capillary Dimensions
0.02" ID x 18"
Shear Rate
1000/sec
Temperature Range
15-150 degrees C
Output Signals
0-10 V
Dimensions
17.5" W x 17.5" D x 9.5" H
Weight
40 lbs
Power Requirements
120 V, 50-60 Hz, 5 A
microlab 600 single syringe pump
Specification
 
Number of Syringes
1
Syringe Volume
10 ml
Dimensions
5.5" W x 7" D x 10.5" H
Weight
13 lbs
erc-3215a degasser
Specification
 
Number of Channels
2
Dimensions
2.8" W x 12.2" D x 5.4" H
Weight
11.2 lbs
data system
Specification
 
Computer Type
Windows 7 Pro, i3 processor, 4 GB RAM, 200 GB HDD
Computer Dimensions
6.9" W x 17.1" D x 14.2" H (Full Tower)
Monitor
22" widescreen flatscreen monitor
Printer Type
Multifunction (print, scan, copy) inkjet printer
Printer Dimensions
17.5" W x 14.5" D x 5" H
ARV Software
Version 2.07
gilson 223 autosampler
Specification
 
Sample Tray Capacity
40 vials
Vial Volume
40 ml
Injection Volume
10 ml
Operating Temperature
15-40 degrees C (not controlled)
Humidity
35% - 80% non-condensing
Dimensions
20.9" W x 17.3" D x 14.6" H
Weight
41 lbs
Power Supply
100-240 V, 50-60 Hz
Download Brochure
View Demo Videos
Read Application Notes
Request a Quote

VIEW OTHER DILUTE SOLUTION VISCOMETRY PACKAGES

Picture
Manual Package
Picture
Semi-Automation Package
Picture
Full Automation Package

Location

Contact Us

2380 Dickinson Ave Suite A
Dickinson, TX 77539
​
Office: 281-678-8549
  • Home
  • About
  • News
  • Products
    • CALPAS Products >
      • CALPAS-V
      • CALPAS-VR
      • CALPAS-R
      • CALPAS-F
      • CALPAS-W
      • CALPAS-K
      • CALPAS-T
      • Qualifications
    • Linkoptik Products >
      • LT2200
      • LT2200E
      • LT3600
      • LT3600 Plus
      • Hydrolink
      • Hydrolink SE
      • Hydrolink SV
      • Aerolink
      • Spraylink
      • Qualifications
    • DSV Products >
      • Y501 Viscometer
      • DSV Packages >
        • Manual Package
        • Autosampler Package
        • Semi-Automation Package
        • Full Automation Package
      • Backflush Kit
    • GPC/SEC Products >
      • Aqueous Columns
      • Organic Columns
      • Specialty Columns
      • Standards
  • Services
  • Learning
    • Linkoptik Learning >
      • Linkoptik Application Notes
    • DSV Learning >
      • Principles of Dilute Solution Viscosity
      • DSV Application Notes
      • Troubleshooting FAQ
      • DSV Demo Videos
      • QuickStart Guide
      • Reboot Protocol
      • DSV School
    • GPC/SEC Learning >
      • GPC/SEC Application Notes
  • Support
    • Linkoptik Technical Support
    • DSV Technical Support
  • Contact Us