• Home
  • About
  • News
  • Products
    • CALPAS Products >
      • CALPAS-V
      • CALPAS-VR
      • CALPAS-R
      • CALPAS-F
      • CALPAS-W
      • CALPAS-K
      • CALPAS-T
      • Qualifications
    • Linkoptik Products >
      • LT2200
      • LT2200E
      • LT3600
      • LT3600 Plus
      • Hydrolink
      • Hydrolink SE
      • Hydrolink SV
      • Aerolink
      • Spraylink
      • Qualifications
    • DSV Products >
      • Y501 Viscometer
      • DSV Packages >
        • Manual Package
        • Autosampler Package
        • Semi-Automation Package
        • Full Automation Package
      • Backflush Kit
    • GPC/SEC Products >
      • Aqueous Columns
      • Organic Columns
      • Specialty Columns
      • Standards
  • Services
  • Learning
    • Linkoptik Learning >
      • Linkoptik Application Notes
    • DSV Learning >
      • Principles of Dilute Solution Viscosity
      • DSV Application Notes
      • Troubleshooting FAQ
      • DSV Demo Videos
      • QuickStart Guide
      • Reboot Protocol
      • DSV School
    • GPC/SEC Learning >
      • GPC/SEC Application Notes
  • Support
    • Linkoptik Technical Support
    • DSV Technical Support
  • Contact Us
Houston MJ Associates
  • Home
  • About
  • News
  • Products
    • CALPAS Products >
      • CALPAS-V
      • CALPAS-VR
      • CALPAS-R
      • CALPAS-F
      • CALPAS-W
      • CALPAS-K
      • CALPAS-T
      • Qualifications
    • Linkoptik Products >
      • LT2200
      • LT2200E
      • LT3600
      • LT3600 Plus
      • Hydrolink
      • Hydrolink SE
      • Hydrolink SV
      • Aerolink
      • Spraylink
      • Qualifications
    • DSV Products >
      • Y501 Viscometer
      • DSV Packages >
        • Manual Package
        • Autosampler Package
        • Semi-Automation Package
        • Full Automation Package
      • Backflush Kit
    • GPC/SEC Products >
      • Aqueous Columns
      • Organic Columns
      • Specialty Columns
      • Standards
  • Services
  • Learning
    • Linkoptik Learning >
      • Linkoptik Application Notes
    • DSV Learning >
      • Principles of Dilute Solution Viscosity
      • DSV Application Notes
      • Troubleshooting FAQ
      • DSV Demo Videos
      • QuickStart Guide
      • Reboot Protocol
      • DSV School
    • GPC/SEC Learning >
      • GPC/SEC Application Notes
  • Support
    • Linkoptik Technical Support
    • DSV Technical Support
  • Contact Us

News

GPC/SEC/DSV Sample Analysis Service

12/3/2020

3 Comments

 
Dear Valued Customers:

We are pleased to announce the creation of a new HMJ GPC/SEC/DSV sample analysis service platform for our polymer/biopolymer customers that is differentiated by expertise, reliability, and cost.  Our most innovative offering is a set of 9 TDAmax (Triple/Tetra) GPC/SEC systems and a set of 4 DSV systems that is capable of providing 3-day turnaround time for routine samples.  

The set of GPC/SEC instruments includes:

Routine GPC Analysis:     Instrument for nonpolar polymers (e.g., PS in THF)
                                            Instrument for neutral aqueous polymers (e.g., PEO in Water)
                                            Instrument for standard FIPA-XS (e.g., PP in THF)

Non-Routine GPC Analysis:    Instrument for polar polymers (e.g., PAN in DMF)
                                                    Instrument for cationic polymers (e.g., PEI in Acetic Acid)
                                                    Instrument for proteins (e.g., BSA in PBS)
                                                    Instrument for special FIPA-XSAI (e.g., ICP/EPR in Tetralin)
                                                    Instrument for method development

The set of DSV instruments includes:    HTDSV for Polyolefins (e.g., PP in Decalin)
                                                                     DSV for Polyamides (e.g., Nylon in Formic Acid)
                                                                     DSV for PVC (e.g., PVC in THF or Cyclohexanone)
                                                                     DSV for PET (e.g., PET in 60/40, Phenol/TCE)
                                                                     DSV for method development

The range of applications offered by these 13 instruments probably covers 80% of typical customer needs.  Application information is provided in our Learning section of our website so that customers can choose the correct method for their samples.  More difficult or research-type samples can be handled on a method development basis.  For more information and sample submission procedure, please browse the Services section of our website.  

If you want to establish direct contact with us, please send a note to one of the following email addresses: weisenwong@hmjassociates.com or shawnwelch@hmjassociates.com.  Once again, thank you very much for your continued support.  We look forward to working with you in the future.  

Sincerely, 

Wei Sen Wong, Ph.D.

weisenwong@hmjassociates.com
3 Comments
Learn More link
8/5/2022 11:19:12 am

Application information is provided in our Learning section of our website so that customers can choose the correct method for their samples. I truly appreciate your great post!

Reply
chat support services link
10/1/2022 08:43:12 am

For more information and sample submission procedure, please browse the Services section of our website. Thank you for the beautiful post!

Reply
Hayden Spence link
10/9/2022 12:42:25 pm

Particularly risk this pay recognize identify. Point list TV although series policy. Difference piece also first.

Reply



Leave a Reply.

Location

Contact Us

2380 Dickinson Ave Suite A
Dickinson, TX 77539
​
Office: 281-678-8549
  • Home
  • About
  • News
  • Products
    • CALPAS Products >
      • CALPAS-V
      • CALPAS-VR
      • CALPAS-R
      • CALPAS-F
      • CALPAS-W
      • CALPAS-K
      • CALPAS-T
      • Qualifications
    • Linkoptik Products >
      • LT2200
      • LT2200E
      • LT3600
      • LT3600 Plus
      • Hydrolink
      • Hydrolink SE
      • Hydrolink SV
      • Aerolink
      • Spraylink
      • Qualifications
    • DSV Products >
      • Y501 Viscometer
      • DSV Packages >
        • Manual Package
        • Autosampler Package
        • Semi-Automation Package
        • Full Automation Package
      • Backflush Kit
    • GPC/SEC Products >
      • Aqueous Columns
      • Organic Columns
      • Specialty Columns
      • Standards
  • Services
  • Learning
    • Linkoptik Learning >
      • Linkoptik Application Notes
    • DSV Learning >
      • Principles of Dilute Solution Viscosity
      • DSV Application Notes
      • Troubleshooting FAQ
      • DSV Demo Videos
      • QuickStart Guide
      • Reboot Protocol
      • DSV School
    • GPC/SEC Learning >
      • GPC/SEC Application Notes
  • Support
    • Linkoptik Technical Support
    • DSV Technical Support
  • Contact Us